According to the Upc, the Distance Between Your Trap and the Vent Should Be No More Than 6 Feet. in Other Words, for the Vent to Work Properly, It Needs to...
According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.
How far can a toilet vent be from toilet?
That means your fixture drain can have an unlimited distance (909.1). Keep in mind your toilet still needs a vent, but your trap arm can be as long as necessary. Now on the other hand, if your plumbing code is the UPC, they're not as generous… In the UPC, the toilet's trap to vent distance is limited to 6 feet.
So yes the shower can also be vented by the wet vent along with the toilet. There is one major stipulation when wet venting multiple fixtures when a toilet is one of them: the toilet must be the last fixture connected to the wet vent.